Normalized energy use

I'm trying to get the normalized energy use values from the M&V module, but I can only find the savings. Is it possible to get the pre and post usage numbers without exporting the data and calculating it myself?

Solved

For anyone else trying to find an answer to this, here are the steps as of version v3.0.1708.2913:
1. View->Show Hidden Channels
2. Channels-> Look for files that end with .AdjustedBaselineModel and .AdjustedPostImplementationModel (these will be the same file names shown in the legend of the Normalized Energy Savings tab).
3. Right click and export the data.